- Home /
- Battery and Tank Monitoring /
- Simarine Monitoring Systems /
- Simarine Shunts and Components /
- SCQ50 50A QUADRO SHUNT
Shop Now
- Autopilot System
- Battery Accessories
- Battery and Tank Monitoring
- Battery Chargers
- Bilge Pump and Water Pump
- Charts
- Compasses
-
CRC/ADOS Products
- Additives-Fuel/Oil/Radiator
- Adhesives/Solvents
- Aerosol Paints
- Brake Cleaners
- Car Care
- Cleaners and Degreasers
- Corrosion Prevention Compounds
- CRC 5.56 Marine Multi Purpose Lubricants
- CRC Specialty Products
- Epoxies and Resins
- Epoxy Mortar
- Fillers
- Food Grade Range
- Gasket/Joint Compounds
- Grooming/Valet
- Lubricants/Silicone Sprays/Grease
- Outdoor Cleaners
- Sealants
- Diesel Heating and Cooking
- Electrical Accessories
- Enerdrive Power Systems
- Inverters
- Inverters Chargers
- Jump Starters
- LED Worklights
- Lithium Batteries
- Marine Antennas
- Marine Audio
- Marine Cameras
- Marine Instruments
- Marine Lighting
- Marine Mounting Systems
- Marine Steering Systems
- Multifunction Displays
- Network
- Radars
- Remote Contolled Spotlights
- Salt Removal
- Satelite TV Systems
- Solar Products
- Thruster Systems
- Transducers
- Trim Tab Systems
- VHF Radios
Brands
SCQ50 50A QUADRO SHUNT
Description
SCQ50 is an innovative shunt module with four inputs for monitoring individual consumer and generator continuous currents up to 50A (35A peak) per input on 12V and 24V systems. That is very convenient for monitoring smaller consumers like refrigerator or generators like solar, wind, hydro or shore power. The current channels can be combined for higher amperage, meaning the continuous currents on the combined channels up to 50A (70A peak) on 12V and 24V volts. SCQ50’s innovative protected architecture allows wiring in either negative (low) or positive (high) side. Up to five modules can be connected simultaneously to monitor up to 20 current channels (only on PICO Battery Monitor).
SCQ50 is an innovative shunt module for monitoring individual consumers and generator with 4x current sensors up to 50A each. For 12V and 24V systems.
Operating | |
---|---|
Power source voltage range | 6 – 35 V |
Temparature range | -20 – +70 °C |
Power consumption at 12 V | |
Operating | 3,5 mA |
Current measuring channels | 4 |
Relay (monostable) | |
Maximum Operating Current | 1 A |
Maximum Common Input Voltage | 6 – 30V |
Voltage inputs | |
---|---|
Per channel | 0,01 – 50 A |
Resolution | 0,01 A |
Accuracy | ± 0,6 % |
Sampling rate | 100 ms |
Maximal current | |
Continuous | 50 A |
Peak current (<1 min) | 60 A |
Peak current (<5 sec) | 60 A |
Voltage drop at 50 A | 35 mV |
Maximum voltage on connections | 35 V |
Connectivity | Up to |
Current sensors | 4 |
Relay Common Input (COM) | 1 |
Relay Output Normaly Open (NO) | 1 |
Relay Output Normaly Closed (NC) | 1 |
SiCOM RJ9 Sockets | 2 |
Installation and Dimension | |
Dimensions (length x width x depth) | 182 x 80 x 37 mm |
Weight | 230 g |